Nurse Call System Accessories

Portable and plug-in devices that add remote calling options e.g. Pendants and Pressure Mats etc

Get in touch to discuss your requirements
Nurse Call System Accessories
Benefits include:
Nurse Call System Accessories
Nurse Call System Accessories
1. Article 17 of the Regulatory Reform (Fire Safety) Order 2005 (RRO)
2. The Fire Safety (England) Regulations 2022
3. The Code of Practice for Fire Door Assemblies BS 8214:2016
4. BS 476 part 31 and BSEN 1634-3
1. Article 17 of the Regulatory Reform (Fire Safety) Order 2005 (RRO)
2. The Fire Safety (England) Regulations 2022
3. The Code of Practice for Fire Door Assemblies BS 8214:2016
4. BS 476 part 31 and BSEN 1634-3

The Fixfire® Fire Log Book is a must-have tool to contain your Fire Safety records and aid compliance with the Regulatory Reform (Fire Safety) order 2005 (RRO).

  • Robust Ring Binder with tabbed dividers
  • Separate sections for user & engineer entries
  • Covers all your Fire Safety checks from Fire Extinguishers and Fire Alarms through to Emergency Lighting and Fire Doors
  • Fire Safety Training section
  • Stores your certificates and as installed information too
  • Optional Separate Lockable storage Cabinet.
FIND OUT MORE
Fixfire Log Book and cabinet
Fire Safety Compliance System™

The Fire Safety Compliance System™ is everything you could want from a single provider to support your ongoing compliance journey.

FIND OUT MORE
FAQ
1. What are fire doors?
2. Why are fire doors so important?
3. How do fire doors work?
4. What are fire doors made of?
5. How long do Fire Doors hold fires from spreading?
6. Are fire doors a legal requirement?
7. Who can fit & maintain fire doors?
8. Why do fire doors need to be inspected and maintained?
9. What is a fire door inspection?
10. Why choose Fixfire’s fire door service?
11. What services do we offer?
Get in touch to discuss your requirements
FAQ
1. Who can fit & maintain fire doors?
2. Why do fire doors need to be inspected and maintained?
3. Are fire doors a legal requirement?
4. Who can fit & maintain fire doors?
5. Why do fire doors need to be inspected and maintained?
6. What is a fire door inspection?
7. Why choose Fixfire’s fire door service?
8. What services do we offer?
Get in touch to discuss your requirements

In order to ensure that your systems and equipment are safely installed and maintained to the highest standards, Fixfire® is accredited by the following bodies.

UKAS Management certification
Certificate No.
442192
Fire Industry Association F-Gas certified
F-Gas Certificate No.
F-0120-GB
Safe Contractor Approved
Certificate No.
MJ5612
Constructionline
Registration No.
97355
BAFE
Apollo Partner
Citation Approved

Download our latest Construction Site Fire Safety Catalogue!

This latest edition is packed with proven rugged products from Fire Extinguishers and ancillaries to Passive Fire Protection Products including Fire & Smoke Seals and Intumescent Pipe Collars. Most items are available for next day delivery or installation/maintenance by our engineers.

Our helpful Sales Team is always available to provide advice and product support.

We look forward to serving you.

CLICK HERE TO DOWNLOAD
Nurse Call System Accessories
Download Catalogues & Guides
Downloads
Fixfire - Delivering smarter solutions to compliance, creating safer environments, saving lives and providing peace of mind

Nurse Call System Accessories

Portable and plug-in devices that add remote calling options e.g. Pendants and Pressure Mats etc

If you'd prefer to order a hardcopy, please complete the following short form to order your Signs Catalogue:

Thank you! Your catalogue will be with you soon.
Oops! Something went wrong while submitting the form.
Download/order your copy of the 2022-23 Signs Catalogue today:
Please note this document will be downloaded via Dropbox. If you do not have a Dropbox account, please click on ‘No thanks, continue to view’ and document will download to your device.
Download your copy of ‘COVID-19 Safety Signage Catalogue July 2021'
Losing footfall due to COVID-19? Download our Retail Signage Catalogue

Fixfire® supplies a comprehensive range of ‘plug and play’ accessories that are compatible with most call systems.

Patient Call System Accessories

  • Standard Call Leads

Intercall®

Compatible with all Intercall® systems manufactured since 2005. For earlier versions and other systems which use a mono jack connector.

Quantec and Nursecall 800

Compatible with all Quantec and Nursecall 800 systems.

SAS

Compatible with Network II call systems.

  • Special Call Leads

The following special call leads are supplied as standard for use with InterCall® systems.

Disc-Alert

Disc-Alert is used by patients with sufficient motor skills to either press or lean on the pad to activate a call. It has a large circular shape and soft vinyl pad design with gripping feet to help keep it in position.

Bulb-Alert

Bulb-Alert is used by patients with sufficient motor skills to either press or lean on the bulb to activate a call. It has an oval-shaped, soft final bulb design that prevents it from rolling off the patient’s bed.

Head-Alert

Head-Alert is used by patients with sufficient motor skills to either press or lean on the pad with their head to activate a call. Head-Alert features a large soft elliptical air activated touch surface.

Breath-Alert

Breath-Alert provides patients with no motor skills a means to communicate by simply breathing into a sensitive pressure-operated switch. With a clamp providing easy attachment to a fixed support such as a bed or wheelchair, Breathcall incorporates a vinyl-covered flexible gooseneck which may be positioned to suit patient requirements.

Two models are available, a standard which has 3ft gooseneck and universal screw clamp for secure mounting and lightweight which has a 2ft gooseneck and ‘bulldog-clip’ type spring clamp. Both models come with a pack of disposable filters which should be changed regularly. Spare filters are available in packs of 12.

Exit-Alert

Exit-Alert is used to detect wandering.

A plastic clip connected to a short cord is attached to the patient and the other end is clipped on to the Exit-Alert unit which is in turn clamped to a fixed location, for example, a chair or bed. If the patient moves away from the Exit-Alert location, the clip disconnects and a call is generated.

  • ‍Remote Pendants

The modern replacement for conventional call leads, remote pendants provide a portable calling facility with none of the problems associated with trailing cables. Note that the devices will not work without appropriate receivers. If you are unsure whether your system is compatible please contact Customer Support.

  • ‍Call Mats

Floor Pressure Mat

A key element of most fall protection strategies, floor pressure mats provide simple detection of patient wandering. Typically placed alongside a bed at night or in front of a chair during the day, the mats plug into the call system via a lead with an appropriate connector to suit the call system. Two types are listed; please contact an advisor who will provide the correct part number for mats compatible with other systems.

Chair Pressure Mat

Chair Pressure Mats provide another means of detecting wandering and thereby preventing falls. Manufactured from antibacterial thermoplastic and measuring 840x500mm they have a recommended working life of 1 year and come fitted with a lead and RJ11 4P4C connector designed to suit Mat-Alert and VersAlert monitors.

Bed Pressure Mat

Bed Pressure Mats are another important method of fall prevention. Manufactured from antibacterial thermoplastic and measuring 380x300mm they have a recommended working life of 1 year and come fitted with a lead and RJ11 4P4C connector designed to suit Mat-Alert and VersAlert monitors.

  • Monitor units

CareAlert monitor and interface units are designed for ready connection to chair and bed mats and provide alarm and interface functions. In all cases, the units incorporate both an integral alarm sounder and an output connector for signalling to local call system via leads available separately.

Mat-Alert Monitor & Kits

Mat-Alert Monitor combines the following features:

  1. RJ11 socket to accept input from chair/bed matI
  2. integral audible alarm
  3. Switchable 2-second delay feature to prevent transient alarms (does not apply to call system output)
  4. PP3 9V battery powered* with a low-battery indicator. Optional mains adaptor available
  5. Durable design with smooth rounded edges
  6. Spring clip for easy mounting
  7. Optional universal mounting bracket available, ideal for clipping to a side of bed or wheelchair

*Battery life depends on usage but 1 month is typical

VersAlert Monitor and Kits

VersAlert Monitor combines the following features:

  1. RJ11 socket to accept input from chair/bed mat
  2. Integral audible alarm
  3. Switchable 2sec/10min/20min/60min delay feature; when the patient leaves mat delay starts. Alarm only occurs if they do not return before the delay expires
  4. Supplied with Mains plug-top power supply unit and mounting bracket pictured
  5. Floor mat mode allows standalone monitoring of Floor mats
  6. May be powered from 2 x AAA battery if mains power is not available. (Batteries not supplied)

Infrared-Alert

Another neat solution in the effort to combat falls, Infrared-Alert allows easy detection of patient movement. Supplied with a C-clamp and Velcro strips for easy mounting, Infrared-Alert is typically set up alongside patient beds or across doorways and generates an audible alarm when movement is detected. The unit also features two sockets; one provides an output signal to the local call system via optional leads and one is for connection to a mains power adaptor also available as an accessory. An optional extension mounting bracket is also offered.

Monitor Connection Leads

A selection of connection leads are available to link monitors to call systems. Popular types are listed but most systems can be catered for - please enquire for further information.

Prox-Alert Ultra-thin Proximity Pad

The ultimate in Fall detection, the new patent-protected Ultra-thin proximity pad works by sensing proximity rather than pressure. Applicable to both chair and bed situations, the technology can sense movement at a much earlier stage than conventional pressure-operated devices. In the case of patients seated in a lounge chair, the sensor would typically be located on the back of the chair. As a patient leans forward to start lifting themselves out of the chair the sensor will detect that the patient’s body is no longer in proximity to the pad and signal an alarm condition. Made from the microporous film the sensor pad is paper-thin and flexible yet immensely strong and durable. The film is also breathable and more comfortable for the patient than conventional pressure pads which are essentially non-breathable and prone to cause sweating. Each pad comes complete with a small electronics module and connection lead configured to suit specific call systems.

KeyCall® is a revolutionary patent-granted Key Operated Fire Alarm Activation Device which has been developed specifically for ‘approved’ applications where standard fire alarm call points would be vulnerable to abuse. Developed by Fixfire® in response to growing demand from the Mental Health Care sector, KeyCall® is a revolutionary one-piece analogue addressable key operated manual call point.

Compatible with a wide range of Conventional and Addressable Fire Alarm Systems.

KeyCall® accepts a Euro-Profile style cylinder
Typically suited/keyed-alike cylinders are fitted so that authorised persons can activate KeyCall® using their standard door key.

Key ‘Click-latch’ mechanism ensures key ‘latches’ in correct position to activate Fire Alarm System.

Anti-ligature low-profile flush-mounting design.

Neat minimalistic one piece construction incorporating Fire Alarm interface module.

Red fire indicator illuminates when KeyCall® is activated.

Compatible with a wide range of Conventional and Addressable Fire Alarm Systems

Applications include:

  • Prisons
  • Mental Healthcare
  • Special Educational Needs (SEN) School
Watch the Video:  AlertLog™ - How to automate your Fire Alarm Weekly Testing
Watch the Video:  AlertLog™ Mobile Notifications Demo

Awaiting image

Awaiting image

Awaiting image

British Standard Design requirements...
  • Install AFD to voids greater than 800mm
  • Treat downward projections exceeding 10% of the void depth as wall
BS5839-Part 1:2013 states:

22.2d) If the system Category is such that automatic fire detection should be provided in any area that contains a horizontal void of 800 mm or more in height, automatic fire detection should also be provided in the void.

22.3j) Ceiling obstructions, such as structural beams, deeper than 10% of the overall ceiling height should be treated as walls [see Figure 10a)]. NOTE 10 Within horizontal voids, beams or obstructions that are deeper than 10% of the overall depth of the void regardless of whether the void is above the ceiling or below the floor, ought to be treated as walls that subdivide the void.

VoidAlert Remote Indicator
Related Downloads
Related Downloads
Related Products & Services
No items found.
The Fixfire Fire Safety Compliance System

Click a sector to find out more

Fixfire® supplies a comprehensive range of ‘plug and play’ accessories that are compatible with most call systems.

Patient Call System Accessories

  • Standard Call Leads

Intercall®

Compatible with all Intercall® systems manufactured since 2005. For earlier versions and other systems which use a mono jack connector.

Quantec and Nursecall 800

Compatible with all Quantec and Nursecall 800 systems.

SAS

Compatible with Network II call systems.

  • Special Call Leads

The following special call leads are supplied as standard for use with InterCall® systems.

Disc-Alert

Disc-Alert is used by patients with sufficient motor skills to either press or lean on the pad to activate a call. It has a large circular shape and soft vinyl pad design with gripping feet to help keep it in position.

Bulb-Alert

Bulb-Alert is used by patients with sufficient motor skills to either press or lean on the bulb to activate a call. It has an oval-shaped, soft final bulb design that prevents it from rolling off the patient’s bed.

Head-Alert

Head-Alert is used by patients with sufficient motor skills to either press or lean on the pad with their head to activate a call. Head-Alert features a large soft elliptical air activated touch surface.

Breath-Alert

Breath-Alert provides patients with no motor skills a means to communicate by simply breathing into a sensitive pressure-operated switch. With a clamp providing easy attachment to a fixed support such as a bed or wheelchair, Breathcall incorporates a vinyl-covered flexible gooseneck which may be positioned to suit patient requirements.

Two models are available, a standard which has 3ft gooseneck and universal screw clamp for secure mounting and lightweight which has a 2ft gooseneck and ‘bulldog-clip’ type spring clamp. Both models come with a pack of disposable filters which should be changed regularly. Spare filters are available in packs of 12.

Exit-Alert

Exit-Alert is used to detect wandering.

A plastic clip connected to a short cord is attached to the patient and the other end is clipped on to the Exit-Alert unit which is in turn clamped to a fixed location, for example, a chair or bed. If the patient moves away from the Exit-Alert location, the clip disconnects and a call is generated.

  • ‍Remote Pendants

The modern replacement for conventional call leads, remote pendants provide a portable calling facility with none of the problems associated with trailing cables. Note that the devices will not work without appropriate receivers. If you are unsure whether your system is compatible please contact Customer Support.

  • ‍Call Mats

Floor Pressure Mat

A key element of most fall protection strategies, floor pressure mats provide simple detection of patient wandering. Typically placed alongside a bed at night or in front of a chair during the day, the mats plug into the call system via a lead with an appropriate connector to suit the call system. Two types are listed; please contact an advisor who will provide the correct part number for mats compatible with other systems.

Chair Pressure Mat

Chair Pressure Mats provide another means of detecting wandering and thereby preventing falls. Manufactured from antibacterial thermoplastic and measuring 840x500mm they have a recommended working life of 1 year and come fitted with a lead and RJ11 4P4C connector designed to suit Mat-Alert and VersAlert monitors.

Bed Pressure Mat

Bed Pressure Mats are another important method of fall prevention. Manufactured from antibacterial thermoplastic and measuring 380x300mm they have a recommended working life of 1 year and come fitted with a lead and RJ11 4P4C connector designed to suit Mat-Alert and VersAlert monitors.

  • Monitor units

CareAlert monitor and interface units are designed for ready connection to chair and bed mats and provide alarm and interface functions. In all cases, the units incorporate both an integral alarm sounder and an output connector for signalling to local call system via leads available separately.

Mat-Alert Monitor & Kits

Mat-Alert Monitor combines the following features:

  1. RJ11 socket to accept input from chair/bed matI
  2. integral audible alarm
  3. Switchable 2-second delay feature to prevent transient alarms (does not apply to call system output)
  4. PP3 9V battery powered* with a low-battery indicator. Optional mains adaptor available
  5. Durable design with smooth rounded edges
  6. Spring clip for easy mounting
  7. Optional universal mounting bracket available, ideal for clipping to a side of bed or wheelchair

*Battery life depends on usage but 1 month is typical

VersAlert Monitor and Kits

VersAlert Monitor combines the following features:

  1. RJ11 socket to accept input from chair/bed mat
  2. Integral audible alarm
  3. Switchable 2sec/10min/20min/60min delay feature; when the patient leaves mat delay starts. Alarm only occurs if they do not return before the delay expires
  4. Supplied with Mains plug-top power supply unit and mounting bracket pictured
  5. Floor mat mode allows standalone monitoring of Floor mats
  6. May be powered from 2 x AAA battery if mains power is not available. (Batteries not supplied)

Infrared-Alert

Another neat solution in the effort to combat falls, Infrared-Alert allows easy detection of patient movement. Supplied with a C-clamp and Velcro strips for easy mounting, Infrared-Alert is typically set up alongside patient beds or across doorways and generates an audible alarm when movement is detected. The unit also features two sockets; one provides an output signal to the local call system via optional leads and one is for connection to a mains power adaptor also available as an accessory. An optional extension mounting bracket is also offered.

Monitor Connection Leads

A selection of connection leads are available to link monitors to call systems. Popular types are listed but most systems can be catered for - please enquire for further information.

Prox-Alert Ultra-thin Proximity Pad

The ultimate in Fall detection, the new patent-protected Ultra-thin proximity pad works by sensing proximity rather than pressure. Applicable to both chair and bed situations, the technology can sense movement at a much earlier stage than conventional pressure-operated devices. In the case of patients seated in a lounge chair, the sensor would typically be located on the back of the chair. As a patient leans forward to start lifting themselves out of the chair the sensor will detect that the patient’s body is no longer in proximity to the pad and signal an alarm condition. Made from the microporous film the sensor pad is paper-thin and flexible yet immensely strong and durable. The film is also breathable and more comfortable for the patient than conventional pressure pads which are essentially non-breathable and prone to cause sweating. Each pad comes complete with a small electronics module and connection lead configured to suit specific call systems.

Read More...
Patient Call System Accessories
Standard Call Leads
Intercall

Compatible with all Intercall® systems manufactured since 2005. (Includes all Intercall® 700 systems. For earlier versions and other systems which use a mono-jack connector see ‘Other Systems’.

NALL100 (2m)
NALL101 (4m)
NALL102 (6m)

Styled 2m ,4m and 6m pear push wander lead with reassurance light.

NALL200

Styled 2m call and bed light control handset. For Intercall® systems with overbed light switching facility

Other Systems

CareAlert offers an extensive range of call leads and accessories to suit the majority of Call Systems.

Other Systems

Please call Customer Support with your specific requirements and we will be glad to help.

Quantec & Nursecall 800

Compatible with all Quantec and Nursecall 800 systems.

NALC100 (1.8m)
NALC101 (4.2m)

1.8m or 4.2 tail call lead.

Disc-Alert

Disc-Alert is used by patients with sufficient motor skills to either press or lean on the pad to activate a call. It has a large circular shape and soft vinyl pad design with gripping feet to help keep it in position.

Bulb-Alert

Bulb-Alert is used by patients with sufficient motor skills to either press or lean on the bulb to activate a call. It has an oval shaped, soft final bulb design that prevents it from rolling off the patient’s bed.

NAAD200

Bulb-Alert with 6ft lead, compatible with Intercall® Systems.

NAAD100

Disc-Alert with 6ft lead or head-Alert with 8ft length compatible with Intercall® Systems.

NAAD300

Head-Alert with 8ft length lead compatible with Intercall® Systems.

Head-Alert

Head-Alert is used by patients with sufficient motor skills to either press or lean on the pad with their head to activate a call. Head-Alert features a large soft elliptical
air activated touch surface.

Breath-Alert

Breath-Alert provides patients with no motor skills a means to communicate by simply breathing into a sensitive pressure-operated switch. With a clamp providing easy attachment to a fixed support such as a bed or wheelchair, Breathcall incorporates a vinyl-covered flexible gooseneck which may be positioned to suit patient requirements. Two models are available, standard which has 3ft gooseneck and universal screw clamp for secure mounting and lightweight which has a 2ft gooseneck and ‘bulldog-clip’ type spring clamp. Both models come with a pack of disposable filters which should be changed regularly. Spare filters are available in packs of 12.

NAAD400

Standard Breath-Alert Unit complete with 9ft call lead, compatible with Intercall® Systems.

NAAD401

Lightweight Breath-Alert Unit complete with 9ft call lead, compatible with Intercall® Systems.

NAAD402

Breath-Alert Accessory Pack complete with 12 filter assemblies with soft straws and porous plastic filters.

Special Call Leads
Related Products & Services
Related Case Studies
Free site assessments, personal service & helpful advice. Contact us today!
Contact us today
08000 891 999
GET IN TOUCH