Fire Door Inspection & Maintenance
RemotestTM High Level Self Testing Smoke Detection
Fixfire® offers full inspection including doors, frames and hardware
Fire doors play a critical role in protecting buildings from the spread of fire and smoke.
However, without proper maintenance and inspection, fire doors may not function properly in the event of a fire, putting lives and property at risk.


- Free Surveys
- Fire Door Inspection
- Fire Door Maintenance & Repairs
- Installation of Fire Doors
- Free Surveys
- Fire Door Inspection
- Fire Door Maintenance & Repairs
- Installation of Fire Doors

- Free Surveys
- Fire Door Inspection
- Fire Door Maintenance & Repairs
- Installation of Fire Doors
- Free Surveys
- Fire Door Inspection
- Fire Door Maintenance & Repairs
- Installation of Fire Doors

- Installation of Magnetic Door Retainers
- Installation of Magnetic Electromagnetic Door Closers
- Comprehensive Reporting for Audit Trails
- Fire Risk Assessments

As a result of recent tragedies, Fire Doors are increasingly under the spotlight. The Fire Safety Order places an obligation on those that have control of a building to maintain Fire Doors must be kept in effective working order.
The changes to the law add additional requirements for inspecting doors, and you will find that remedial works will be required from time to time.
In order to comply with BS9999:2017 (Fire safety in the design management and use of buildings – Code of practice) all fire doors should be inspected every six months.
In particular, it should be ensured that:
- Heat-activated seals and smoke seals are undamaged;
- Door leaves are not structurally damaged or excessively bowed or deformed;
- Gaps between the door leaf and the frame are not so small as to be likely to bind, or so large as to prevent effective fire and smoke-sealing;
- Hanging devices, securing devices, self-closing devices and automatic release mechanisms are operating correctly.

How does Remotest™ work?
Remotest™ incorporates a concealed arm which is remotely actuated and rotates and positions in front of the OSID detector, proving both ‘Fault’ and ‘Fire’ functionality.
The self-test function is either configured to operate via the Fire Alarm system or built in Wi-Fi operated via an internet browser.
Remotest™ requires a low voltage 24v dc supply and incorporates space to accommodate loop powered Fire Alarm modules for Gent by Honeywell and Apollo Fire Detection protocols.


Applications
Their anti-ligature design means that they are perfect for anti-vandal applications, such as for Hospitals, Mental Health Wards and Prisons. The shock-resistant metal faceplate is fitted with anti-tamper screws, ensuring that the detector is completely secure and minimises safety hazards in healthcare and custodial environments.
Fixfire® offer a unique, custom surface-mount option for concrete ceilings, where a hole would have to be cut out for the flush system to be installed. This offers a bolt-on alternative that provides the same anti-tamper solution.
Additionally, the sleek, flat design of flush-mounted detectors offers an aesthetic and discrete solution for environments such as art galleries or luxury hotels. With faceplates available in both white and black, they blend seamlessly into most ceiling finishes, maintaining the visual integrity of interior spaces without compromising on safety.
Installation Conditions
Flush Fire Detectors are only compatible with 24v dc addressable fire alarm systems operating the ‘Apollo’ protocol. As they are not mains or battery powered, they are not typically suitable for small residential premises such as houses or flats and are only used in commercial buildings.
Additionally, Flush Fire Detectors do not come with built-in sounders, so separate audible warning devices must be installed to meet compliance standards. If you're considering these detectors as part of your fire safety solution, it's important to assess whether your current system includes compatible sounders. If not, while there are flush and discreet sounder options available, the additional equipment and installation requirements could lead to higher overall costs than initially expected.
When not to use
It's essential to understand where Flush Fire Detectors may not be appropriate. These detectors are sometimes purchased without full awareness of their intended applications, which can lead to increased costs, delays, and compromised fire safety. To ensure effective protection and compliance, avoid installing Flush Fire Detectors in the following environments:
- Areas exposed to steam, high dust levels, or fumes (bathrooms, kitchens, rest rooms). This is due to the sensors not being able to distinguish the difference between this and smoke.
- Rooms smaller than 1m x 1m.
- Locations without 500mm clearance on all sides.
- Near doorways - door movement can trigger false alarms.
- Close to lights or air conditioning units - may interfere with sensor detection.
- Residential homes - incompatible with domestic detection systems.
- Kitchen applications - smoke-only detection inappropriate for cooking areas.
Download our latest Construction Site Fire Safety Catalogue!
This latest edition is packed with proven rugged products from Fire Extinguishers and ancillaries to Passive Fire Protection Products including Fire & Smoke Seals and Intumescent Pipe Collars. Most items are available for next day delivery or installation/maintenance by our engineers.
Our helpful Sales Team is always available to provide advice and product support.
We look forward to serving you.

The Fixfire® Fire Log Book is a must-have tool to contain your Fire Safety records and aid compliance with the Regulatory Reform (Fire Safety) order 2005 (RRO).
- Robust Ring Binder with tabbed dividers
- Separate sections for user & engineer entries
- Covers all your Fire Safety checks from Fire Extinguishers and Fire Alarms through to Emergency Lighting and Fire Doors
- Fire Safety Training section
- Stores your certificates and as installed information too
- Optional Separate Lockable storage Cabinet.

The Fixfire® Fire Log Book is a must-have tool to contain your Fire Safety records and aid compliance with the Regulatory Reform (Fire Safety) order 2005 (RRO).
- Robust Ring Binder with tabbed dividers
- Separate sections for user & engineer entries
- Covers all your Fire Safety checks from Fire Extinguishers and Fire Alarms through to Emergency Lighting and Fire Doors
- Fire Safety Training section
- Stores your certificates and as installed information too
- Optional Separate Lockable storage Cabinet.

Fire Safety Compliance System™
The Fire Safety Compliance System™ is everything you could want from a single provider to support your ongoing compliance journey.
In order to ensure that your systems and equipment are safely installed and maintained to the highest standards, Fixfire® is accredited by the following bodies.
.webp)
442192

F-0120-GB

MJ5612

97355






